上海洽姆儀器科技有限公司
主營產(chǎn)品: 精密儀器設(shè)備及配件, 耗材, 填料, 試劑, 標(biāo)準(zhǔn)對(duì)照品, 化工中間體, 高純氣體和標(biāo)準(zhǔn)混合氣
Ionic-Liquid-氣相毛細(xì)柱
價(jià)格
訂貨量(根)
¥20055.00
≥1
店鋪主推品 熱銷潛力款
憩憦憪憩憦憩憥憭憩憭憫
在線客服
上海洽姆儀器科技有限公司
店齡6年 企業(yè)認(rèn)證
聯(lián)系人
魏先生
聯(lián)系電話
憩憦憪憩憦憩憥憭憩憭憫
經(jīng)營模式
貿(mào)易商,
所在地區(qū)
上海市閔行區(qū)
- 基本信息
- 品牌:supelco
- 型號(hào):29647-U
- 加工定制:否
- 測量范圍:1
- 測量精度:1
- 分辨率:1
- 電源電壓:1
- 貨號(hào):29647-U
In 2005, Prof. Daniel W. Armstrong (University of Texas at Arlington) showed that dicationic and polycationic ionic liquids could successfully be used as viable GC stationary phases. These consist of two or more organic cations joined by a linkage, and associated with anions, which can be either inorganic or organic. Ionic liquid phases differ physically and chemically from non-ionic liquid stationary phases.
They are much smaller compared to big, bulky polysiloxane polymer and polyethylene glycol phases, plus there are no active hydroxyl groups. These features lead to greater stability, even in the presence of moisture and/or oxygen.
Many modifications are possible to alter selectivity. The base structure can be dicationic or polycationic. There are numerous cation, linkage, and anion choices. Pendant groups can be added to cations and/or linkages.
Ionic liquids have the opportunity to impact current practices along several paths:
Columns can be engineered with identical selectivity to non-ionic liquid columns, but with higher operating temperatures and less susceptibility to damage from moisture and/or oxygen.
Columns can be engineered with completely unique selectivity to non-ionic liquid columns, producing good peak shape and resolution for compounds of varying functionality.
Columns can be used in multidimensional separations, due to their engineered orthogonality and high thermal stability.
28925-U SLB-IL111 15 m × 0.10 mm, df 0.08 μm 28927-U SLB-IL111 30 m × 0.25 mm, df 0.20 μm 28928-U SLB-IL111 60 m × 0.25 mm, df 0.20 μm 29647-U SLB-IL111 100 m × 0.25 mm, df 0.20 μm 28882-U SLB-IL100 15 m × 0.10 mm, df 0.08 μm 28883-U SLB-IL100 20 m × 0.18 mm, df 0.14 μm 28884-U SLB-IL100 30 m × 0.25 mm, df 0.20 μm 28886-U SLB-IL100 60 m × 0.25 mm, df 0.20 μm 28887-U SLB-IL100 30 m × 0.32 mm, df 0.26 μm 28888-U SLB-IL100 60 m × 0.32 mm, df 0.26 μm 29477-U SLB-IL82 15 m × 0.10 mm, df 0.08 μm 29479-U SLB-IL82 30 m × 0.25 mm, df 0.20 μm 28909-U SLB-IL76 15 m × 0.10 mm, df 0.08 μm 28913-U SLB-IL76 30 m × 0.25 mm, df 0.20 μm 28880-U SLB-IL59 15 m × 0.10 mm, df 0.08 μm 28891-U SLB-IL59 30 m × 0.25 mm, df 0.20 μm 29505-U SLB-IL60 30 m × 0.25 mm, df 0.20 μm 29484-U SLB-IL61 15 m × 0.10 mm, df 0.08 μm 29486-U SLB-IL61 30 m × 0.25 mm, df 0.20 μm